HP-YD32 Lightweight Remote Online Monitoring System (32-Channel, 200 Hz Synchronous DAQ)

SKU HP-YD32 Category

HP-YD32 is a lightweight, remote online monitoring and data acquisition (DAQ) system built for long-term, multi-point measurement. With 32 synchronized channels and built-in signal conditioning, it supports mixed sensor inputs—strain, voltage, current, resistance, IEPE accelerometers, magnetic sensors, and more—without extra external modules.

Additional information

True Mixed Inputs per Channel

Connect force/strain/voltage/current/resistance/IEPE/magnetic sensors directly—no additional auxiliary equipment required

200 Hz Synchronous Acquisition

All channels sample, display, and store data simultaneously (max 200 Hz)

Independent Channel Architecture

Dedicated conditioning + high-performance ADC per channel for accuracy and consistency

Strong Anti-Interference

Improves signal integrity in noisy industrial or field environments

Auto Balance (Zeroing)

One-click per-channel balance for clean baselines; supports custom unbalance point settings

High Accuracy Measurement

Built-in precision bridge components and stable conditioning for reliable strain/bridge measurements

Long-Term Stability

Designed for stable readings over extended monitoring periods

Product Details

Product Details

  • Model: HP-YD32

  • Product Type: Lightweight remote online monitoring / multi-channel data acquisition system

  • Core Capability: 32 channels, all-channel synchronous sampling, display, and data storage

  • Mixed-Input Design: Each channel can be configured independently with built-in conditioning circuits for multiple sensor types

  • Measurement Performance: High anti-interference design and long-term stability; measurement accuracy up to ±0.2%

Product Overview

HP-YD32 is designed for engineering tests and continuous monitoring where multiple sensors must be collected at the same time. Each channel includes an independent, high-stability signal amplification/conditioning stage and a high-performance A/D converter to maintain consistency and reliability over long deployments. Automatic balance (zero) helps streamline setup, while manual zero configuration supports special test requirements.

Typical Applications

  • Structural health monitoring (bridges, buildings, tunnels)

  • Geotechnical monitoring (soil/earth pressure, pore water pressure, slope monitoring)

  • Lab or field load testing (force, torque, displacement, strain)

  • Machinery and equipment monitoring (vibration/acceleration, speed, displacement)

  • Industrial process instrumentation (voltage/current loop sensors, 4–20 mA transmitters)

Sensor & Input Support

  • Strain / Bridge Sensors

    • Full bridge, half bridge, quarter bridge (2-wire), quarter bridge (3-wire)

    • Strain-based force, pressure, torque, displacement sensors

  • Voltage Inputs

    • Single-ended voltage, differential voltage

  • Current Inputs

    • Supports current-output sensors (including common transmitter ranges)

  • Temperature

    • Thermocouples (various types)

    • Pt100 RTD

  • Pressure / Load

    • Piezoresistive pressure sensors

    • Load cells (weighing sensors)

    • Pore water pressure gauges, earth pressure gauges (voltage/current output types)

  • Displacement

    • Strain-type, resistive type, LVDT displacement sensors

  • Acceleration / Velocity / Speed

    • IEPE accelerometers (built-in constant current source)

    • Magnetic/electromagnetic type sensors (velocity/speed/displacement)

Parameter Specification

  • Channels (Measurement Points): 32 channels

  • Sampling Rate: Up to 200 Hz (software adjustable)

  • Acquisition Mode: All channels synchronous sampling

  • Mixed Input: Per-channel selectable input type; built-in sensor conditioning circuits

Strain / Bridge

  • Bridge Types: Full / Half / Quarter (2-wire) / Quarter (3-wire)

  • Strain Ranges (selectable): ±3000 με, ±10000 με, ±32768 με, ±100000 με

  • Bridge Excitation: 0–5 V / 100 mA, software setting accuracy 0.1%

Voltage

  • Modes: Single-ended, differential

  • Ranges (selectable): ±50 mV, ±500 mV, ±1 V, ±5 V, ±10 V

Current

  • Ranges: 0–20 mA, 0–40 mA, 0–80 mA

Temperature

  • Thermocouple: 0–1500 °C (various types)

  • Pt100: 0–300 °C

Other Excitation

  • Aux Excitation Voltage: 24 V

  • IEPE Constant Current Source: Built-in 4 mA IEPE supply and conditioning

Performance

  • Measurement Accuracy: ±0.2%

  • Stability (input shorted): ±3 με / 4 hours; ±1 με / °C

FAQ

Q1: Can different channels measure different sensor types at the same time?
Yes. HP-YD32 supports mixed inputs, and each channel can be configured independently (strain/voltage/current/IEPE, etc.).

Q2: What does “synchronous acquisition” mean in real tests?
All channels sample at the same time, which is critical for comparing multi-point data (e.g., load/strain/displacement correlations).

Q3: Is 200 Hz fixed?
No. The sampling rate is software adjustable up to 200 Hz.

Q4: Do I need an external IEPE power module for accelerometers?
No. The system includes a built-in 4 mA constant current source and conditioning circuit for IEPE sensors.

Q5: How do I zero (balance) strain channels before a test?
Each channel supports automatic balance (zeroing). Manual zero/unbalance point settings are also available for special test requirements.

Q6: What voltage/current signal ranges are supported?
Voltage supports single-ended/differential with ranges from ±50 mV up to ±10 V. Current supports 0–20 mA, 0–40 mA, and 0–80 mA.

Q7: What bridge configurations are supported for strain gauges?
Full bridge, half bridge, quarter bridge (2-wire), and quarter bridge (3-wire) are supported, with multiple selectable strain ranges.

Contact with: