HP-DH8 (Handheld) Dynamic Signal Measurement System

SKU HP-DH8 Category

HP-DH8 is a handheld, multi-sensor dynamic signal DAQ system designed for field tests and harsh interference environments, featuring 8-channel synchronous acquisition, 0.1 Hz–256 kHz sampling, and an integrated Windows 10 touchscreen for standalone measurement, analysis, and data storage.

Additional information

True mixed-input, multi-sensor acquisition

Each channel can be configured for different sensor/input types and used at the same time—ideal for multi-physics test setups.

Multi-excitation outputs

Supports multiple constant voltage/current excitation sources, including 0–10 V, +24 V, +12 V, and IEPE 24 V / 4 mA constant current.

Synchronous sampling, display & storage

All channels acquire, display, and save data synchronously; max sampling rate up to 256 kHz with software configuration.

Modular & lightweight design

Easy to carry; measurement points can be customized and combined flexibly for different test scenarios.

Flexible power options for field work

Supports AC 220V/50Hz or DC 12V; built-in 12V lithium battery enables 4 hours of independent operation—well-suited for outdoor impact/explosion tests.

Product Details

Product Overview

HP-DH8 is built for on-site dynamic measurements where portability and reliability matter. In complex electromagnetic interference conditions, it can simultaneously connect different sensor types per channel to capture multiple physical quantities such as shock, vibration, strain, voltage/current, displacement, temperature, and more—without relying on external conditioning modules.


Typical Applications

  • Field vibration & shock tests (IEPE/ICP sensors)

  • Outdoor impact/blast experiments requiring battery-powered DAQ

  • Multi-sensor test setups: strain + voltage/current + displacement + temperature

  • Environments with strong electromagnetic interference where stable acquisition is required


Signal & Sensor Support

  • Acceleration / Speed: IEPE, magnetic, resistive, capacitive types

  • Strain bridge: Full bridge, half bridge, quarter bridge (2-wire / 3-wire), quarter bridge compensation

  • Voltage: ±5 mV to ±10 V

  • Current: ±20 mA, 0–20 mA, 4–20 mA

  • Temperature (thermocouples): 0–1500°C

  • Displacement: strain-type, resistive, inductive, LVDT, eddy current, laser displacement

  • Strain-type transducers: force, pressure, torque, displacement sensors

Parameter Specification
Channels / measurement points 8 channels, all-channel synchronous acquisition
Sampling rate 0.1 Hz–256 kHz, 1 Hz step, software configurable
Measurement type Mixed inputs per channel; supports multiple sensors simultaneously; no external conditioning module required
Front-end excitation (per channel) 0–10 V / 400 mA, software set; accuracy 0.1%
Rear excitation outputs +24 V, +12 V
IEPE constant current Built-in IEPE 4 mA constant current + conditioning circuit
ADC resolution 24-bit
Measurement accuracy ±0.2%
Balance Full-scale independent D/A auto-balance; completes all-channel balance in 5 seconds
Trigger modes Free trigger / external trigger / internal trigger; 4-pin SYNC; isolated DC 5V 0.1A; level & edge recognition
Operating system Built-in Windows 10 host; 8″ capacitive touchscreen; 32GB storage; standalone test/acquisition/analysis
Power Built-in lithium battery; 4 hours operation; suitable for outdoor work

FAQ

Q1: What makes HP-DH8 “handheld” compared to rack DAQ systems?
HP-DH8 integrates Windows 10 + touchscreen + local storage + battery, so it can run tests without an external PC, ideal for field work.

Q2: Can I use IEPE/ICP accelerometers?
Yes. HP-DH8 provides built-in IEPE 4 mA constant current with conditioning.

Q3: Can different sensor types be used at the same time?
Yes. HP-DH8 supports mixed inputs across channels, so you can capture strain, voltage/current, displacement, temperature, acceleration, etc. in one synchronized test.

Contact with: